Abstract
An equimolar mixture of cyclohexane and toluene was separated by simple and fractional distillation, using an empty column and a copper sponge column respectively. Using helium as the mobile phase, the distillate was analyzed through gas chromatography. The calculated HETP for the simple distillation was 8.274 cm/plate and the 3.332 cm/plate for the fractional distillation.
Experimental Procedure
A copper packed fractional-distillation column was obtained and an apparatus was assembled for fractional distillation. Four clean, dry fraction collectors were obtained and labeled HETP, fraction 1, fraction 2, and fraction 3 respectively.
A volume of 40.0 mL of an equimolar mixture of cyclohexane and toluene was added to a 100.0-mL round bottom flask attached to the end of the distillation column. Heating chips were added to the round bottom flask in order to speed up the heating process. The 100.0-mL round bottom flask, along with the distillation column was attached to a ring stand over a heat source. The mixture was delicately heated to a boil.
The first five drops were collected in the vial labeled HETP. The liquid for vial 1 began collecting when the temperature was 60 C and continued until it was 85 C. Vial 2 began collecting when the temperature was 86C and continued until it was 99 C. Vial 3 was collected at room temperature once the remaining liquid cooled. A volume of 1 micro-liter of each fraction, including the HEPT was added to the gas chromatography apparatus separately in order for each fraction to be analyzed. For simple distillation, the same procedure was followed using an empty, clean, and dry column.
Data:
Table 1: Simple Distillation Values
VariablesHETPFraction 1Fraction 2Pot Residue
Temp range, °C-60-8586-100-
Empty Vials & cap, g5.45316.84216.48216.842
Vial & contents, g5.57828.32330.21123.311
Mass of fraction, g0.12511.48113.7296.469
Area GC peak for Cy93.9461.2430.430
Relative mass Cy, g104.2767.97633.7770
% mass Cy93.3692.6349.550
Actual mass Cy, g0.116710.6356.8030
Actual moles Cy0.001390.126.08080
Area GC peak Tol6.684.8730.9874.33
Relative mass Tol, g7.0145.113532.52978.047
% mass Toluene6.647.3750.45100
Actual mass Tol, g0.008384.6156.9266.469
Actual moles Tol0.000090.91770.07510.0702
Table 2: Fractional Distillation Values (Copper Sponge Column) VariablesHETPFraction 1Fraction 2Pot Residue
Temp range, °C67-7071-8586-100-
Empty Vials & cap, g5.30416.52815.73616.031
Vial & contents, g5.41227.14725.26026.200
Mass of fraction, g0.10810.6199.52410.169
Area GC peak for Cy49.4378.2240.000
Relative mass Cy, g54.86786.82444.40
% mass Cy99.588.7663.560
Actual mass Cy, g0.10759.4256.0530
Actual moles Cy0.00130.1120.06570
Area GC peak Tol0.19.9022.9457.86
Relative mass Tol, g0.10510.39524.08760.753
% mass Toluene0.511.2436.44100
Actual mass Tol, g0.00051.1943.47110.169
Actual moles Tol0.0000050.01290.03760.1103
Discussion
The Northern Pines Chemical Company specializes in manufacturing chemicals from wood products such as turpentine.
To obtain pure α-pinene, it must be separated, using fractional distillation, from the other major component turpentine, β-pinene. This company would like to switch to a cheaper and longer-lasting packing material. The objective of this experiment was to separate an equimolar mixture of cyclohexane and toluene by simple and fractional distillation, using an empty column and a copper sponge column respectively. The distillate was analyzed through gas chromatography, using helium as the mobile phase. Helium is a good mobile phase because it acts as an unreactive carrier-gas that pushes the samples through the chromatogram. This information was used to determine which packing material is most effective by comparing HETP values which based on the number of theoretical plates each material provides. Using the copper sponge as packing material in the fractional distillation column provided a very effective separation of cyclohexane and toluene.
The calculated HETP for simple distillation was 8.274 cm/plate and 3.332 cm/plate for fractional distillation. The fractional distillation was more effective because it had a lower HETP value which means that it has a higher number of theoretical plates for the same column length as the simple distillation. When comparing the purity of the major cyclohexane-rich fraction with the starting mixture (the equimolar mixture of cyclohexane and toluene) of each distillation the packing material improved efficiency by more than six percent. One way to recover cyclohexane with even greater purity would be to heat the starting mixture slowly and steadily instead of rapidly, allowing better separation of the components.
Another way to improve purity is to make sure the column is properly packed (not too tight) and insulated. Different packing materials will have diverse efficiency for distillation and therefore yield different HETP values. The most efficient packing material used was “rascing rings,” which provided an HETP of 2.67 cm/plate. The copper sponge material had an HETP value of 3.3 cm/plate, followed by glass beads and coiled copper with 7.5cm/plate and galvanized steel with 12.5 cm/plate. Packing the Northern Pines Chemical Company’s 3ft fractionating column with rascing rings would provide 34.2 plates, which meets the minimum requirement for separating α- and β-pinene.
Exercises
1) HETP=height/plates
Porcelain saddles: 5 cm= (15 cm )/(x )=3 plates
Glass Tube: 15 cm= (15 cm )/x=1 plate
Vigreux Column: 8 cm= (24 cm)/x=3 plates
Total plates= 3+3+1-1(boiling flask) = 6 plates
2) The HETP value and efficiency of separation can be affected by experimental errors. A) If the HETP sample was collected midway through the distillation, the mole fraction of cyclohexane:toluene would be much lower, which would in turn yield a higher HETP value. B) If all of the liquid distilled within 5 minutes of heating, a higher HETP value would be found again because all of the toluene would be distilled as well. This also means poor separation. C) If two packed columns were stacked over the boiling flask instead of one, the HETP value remain the same if the columns were identical because the height and number of plates would be the same.
Remember! This is just a sample.
You can get a custom paper by one of our expert writers.
Get your custom essay
Helping students since 2015
Essay Writing Service Features
Our Experience
No matter how complex your assignment is, we can find the right professional for your specific task. Contact Essay is an essay writing company that hires only the smartest minds to help you with your projects. Our expertise allows us to provide students with high-quality academic writing, editing & proofreading services.Free Features
Free revision policy
$10Free bibliography & reference
$8Free title page
$8Free formatting
$8How Our Essay Writing Service Works
First, you will need to complete an order form. It's not difficult but, in case there is anything you find not to be clear, you may always call us so that we can guide you through it. On the order form, you will need to include some basic information concerning your order: subject, topic, number of pages, etc. We also encourage our clients to upload any relevant information or sources that will help.
Complete the order formOnce we have all the information and instructions that we need, we select the most suitable writer for your assignment. While everything seems to be clear, the writer, who has complete knowledge of the subject, may need clarification from you. It is at that point that you would receive a call or email from us.
Writer’s assignmentAs soon as the writer has finished, it will be delivered both to the website and to your email address so that you will not miss it. If your deadline is close at hand, we will place a call to you to make sure that you receive the paper on time.
Completing the order and download