Identifying an Unknown Contaminant Using Qualitative and Quantitative Tests
INTRODUCTION
Background:
Knowing how to identify chemicals is important in a day-to-day setting because it can be applied in multiple situations. A common situation that should be important to the average person would be on a crime scene investigation. More specifically, it can be used to in the study of forensics. Being able to identify chemicals would be helpful when it comes to drug use or any other illegal use of substances. If chemicals can be identified after they have been dissolved in something, then it would be harder for someone to destroy evidence. In the conducted experiment, common contaminants were used that are commonly found in water samples, but it could be applied to almost any chemical by solubility, flame test, pH test, conductivity, precipitation, and titration. Conducting these tests in a laboratory is important because it is a more controlled environment than doing it out on the field somewhere. Then a test can be properly carried out and the person who committed wrongdoings can be punished accordingly.
Theory:
In this experiment, many tests were carried out including solubility, conductivity, flame test, pH test, precipitation, and titration and each of the tests are classified as qualitative or quantitative. A qualitative analysis is defined as collecting characteristics of an unknown about the reactivity to identify the chemical. Qualitative analysis is preliminary because the quantitative analysis confirms the qualitative. Some examples of quantitative analysis used are solubility, titration, pH test, flame test, etc. To perform the solubility test, DI water, HCl, NaOH, ethanol, and acetone were used as the solvents. Then known and unknown contaminants were taken to dissolve in the multiple liquids. This way there could be a comparison of what the contaminants dissolved in and what they did not. After the solubility test, there were to be two to four substances that could be the unknown. Then recorded which of the solvents dissolved the solutes. Acid-base titration was performed by first taking a pH test to decide whether the solution is acidic or basic. Then depending on results, a base or acid would be added to the solution with an indicator to determine when the mixture is neutral. The pH test was simply performed by putting a pH meter in the solution and reading what the pH was. This test can help for the acid-base titration because then it would be known what to add to make the solution neutral. The flame test is relatively simple because the unknown and a known are burned to see what color the flame is. The colors were to be recorded and compared between a few chemicals. The precipitation reaction is one of the more difficult tests. It was performed by dissolving the unknown in AgNO3 and BaCl2. Then from visual observation it should be possible to see which solution the chemicals dissolved and formed a precipitate. By examining a solubility table, it makes it easier to understand what the precipitate could be. From there the solution needed to be funneled and filtered to get the precipitate by itself and then the precipitate was placed in the oven.
Hypothesis:
Based on visual observations, the hypothesis was that the unknown was either ammonium chloride, calcium chloride, or sodium oxalate. This hypothesis was reached by the visual cues of the white, powdery texture of the substance.
Objectives:
The objective for Week 1 was to perform a solubility and flame test to narrow down the choice of what the unknown could be. The objective of Week 2 was to continue testing to solidify a preliminary answer because it should have been down narrowed down enough. The tests performed during Week 2 were pH levels, titration, conductivity, and precipitation reactions.
METHODS
Part 1 Methods:
The glassware and other tools used in the experiment were four 250 mL beakers, funnel, glass stirring rod, disposable pipettes, Bunsen burner, wire loop, four test tubes, a well plate, and a magnetic stir plate. The contaminants provided were CaCl2, NaNO3, (NH4)2SO4, NH4Cl, MgSO4, Ca(NO3)2, CH3CO2Na, Na2CO3, Na2C2O4, and NaCl. HCl was provided as the acid, NaOH as the base, acetone, DI water, and ethanol.
Solubility Procedure:
Get a well plate and label each row and column of which solute and solvent will be in each well
Get 5 test tubes for the acetone solubility to be tested in
Get DI water, NaOH, HCl, Ethanol, and Acetone in a respective beaker
Use a pipette to distribute the solvents into the well plate and test tubes
Gather the contaminants being testing and place them in each solvent and stir to test solubility
Record results on table of what solute dissolved in which solvent
Conductivity Procedure:
Dissolve 0.2 grams of solute into 100 mL of DI water in a beaker
Use multimeter to test the conductivity of the solution
Record the results and repeat in order to ensure a correct reading
pH Test Procedure:
Use same solution of 1 gram of solute to 100 mL of water in a beaker
Use pH meter to test the acidity or basic levels
Record answers on table
Flame Test Procedure:
Dip wire loop into DI water and pick up some of salt
Put wire loop into Bunsen burner flame
Record what color the chemical burned
Titration Procedure:
If solution is acidic, then place a basic solution into the burette to titrate into the acidic solution
If solution is basic, then place an acidic solution into the burette to titrate into the basic solution
Add pH indicator drops (Phenolphthalein) into beginning solution (will change color when pH is neutral)
Slowly add the base or acid into the solution and wait for the solution to change color to pink
Record the amount added onto the table
Repeat 3 times and take the average
Part 2 Methods:
The glassware and other tools used in the experiment are a filter, funnel, oven, 250 mL beaker, waste bucket, watch glass, and scoopula. The chemicals used were AgNO3 and BaCl and the unknown.
Gravimetric Analysis/Precipitate Reaction Procedure:
Dissolve 1 gram of solute into 250 mL DI water into beaker. Repeat
Add 50 mL of AgNO3 and 50 mL of BaCl2 in respective beakers
Mix well
Observe visually to see which solution precipitates
Take precipitate reaction to funnel with filter paper
Run through machine to get precipitate
Place precipitate on watch glass and put in oven for 10 minutes
Weigh the precipitate and compare to known chemicals
Safety:
Safe
MgSO4
CH3CO2Na
120.366 g/mol
84.026 g/mol
Avoid contact with eyes, skin, and clothing. Wash hands after handling. Wear gloves and goggles. Store safely at room temperature
Skin Irritant
CaCl2
NaNO3
Na2CO3
110.98 g/mol
84.99 g/mol
105.99 g/mol
Be in well ventilated area. Avoid contact with skin, eyes, and clothing. Wash hands after handling. Wear scrub pants, gloves, goggles, and lab coat. Keep away from heat.
Toxic
(NH4)2SO4
NH4Cl
Ca(NO3)2
Na2C2O4
96.06 g/mol
53.49 g/mol
164.088 g/mol
134.0 g/mol
Wear scrub pants, gloves, goggles and lab coat. Be in well ventilated area. Handle carefully and avoid contact with eyes, skin, and clothing. Store in tight container and at room temperature. Avoid heat and release into the environment.
Bunsen Burner
Use precaution when burning. Wear gloves and goggles and avoid direct contact with flame.
Oven
Make sure to have heat resistant gloves and tongs to get products out of the oven. Wear goggles.
MgSO4
Magnesium Sulfate
CaCl2
Calcium Chloride
(NH4)2SO4
Ammonium Sulfate
CH3CO2Na
Sodium Acetate
Na2C2O4
Sodium Oxalate
Ca(NO3)2
Calcium Nitrite
NaNO3
Sodium Nitrate
Na2CO3
Sodium Carbonate
NH4Cl
Ammonium Chloride
RESULTS
Part 1 Results:
Titration was not performed because pH of unknown was neutral
Trial
Acid Volume
(mL)
Base Volume
(mL)
# of indicator drops
Acid (M) Concentration
Base (M) Concentration
1
2
3
Av. Volume
Salts
Water
HCl
NaOH
Ethanol
Acetone
Flame Test
Conductivity
pH
CaCl2
x
x
–
x
x
red
27.8 mS
7
NaNO3
x
–
x
–
–
–
–
–
(NH4)2SO4
x
x
x
–
–
–
–
–
NH4Cl
x
x
x
–
x
No color
–
–
MgSO4
x
x
x
–
–
–
–
–
Ca(NO3)2
x
x
–
x
–
–
–
–
CH3CO2Na
x
x
x
–
–
–
–
–
Na2CO3
–
x
–
–
–
–
–
–
Na2C2O4
–
–
–
–
–
–
–
–
NaCl
x
–
x
–
–
–
–
–
Unknown
x
x
–
x
x
red
27.7 mS
7
Part 2 Results:
Initial unknown mass
Volume of DI water
Reaction/
Precipitate?
Theoretical Yield
Precipitate formed?
Standard deviation/
Percent Error
50 mL of AgNO3
1 gram
250 mL
Yes
2.58 g AgCl
1.78 g AgCl
31%
50 mL of BaCl2
1 gram
250 mL
No
–
–
–
Initial CaCl2 mass
Volume of DI water
Reaction/
Precipitate?
Theoretical Yield
Precipitate formed?
Standard deviation/
Percent Error
50 mL of AgNO3
1 gram
250 mL
Yes
2.58 g AgCl
1.78 g AgCl
31%
50 mL of BaCl2
1 gram
250 mL
No
–
–
–
Calculations:
Precipitate Reactions
CaCl2 + 2 AgNO3 2 AgCl + Ca(NO3)2
Molarity/Volume
M1V1=M2V2
Ex. (100 mL)(M1) = (50 mL)(3.0 M); M1 = 1.5 M
Percent Yield
Percent Error
[(Absolute value of experimental value – exact value) ÷ exact value] x 100 = __%
DISCUSSION
Part 1 Discussion:
The experiment was very similar to the theory, but a few tests were not performed because of the unknown that was received. In the experiment, the solubility test was performed first to narrow down the options of solutes. Then using the flame test it already identified the unknown, but to further confirm the chemical in question, pH tests, conductivity tests, and precipitate reactions were done during week 2. The unknown was known to be CaCl2 because all the testing of the unknown had almost identical results to CaCl2. In the solubility testing, the only chemical that was the same as the unknown was CaCl2. The performed flame test on another chemical, NH4Cl, showed that CaCl2 produced similar results to the unknown. After the flame test was performed, it was observed that the Calcium chloride burned the same color red as the unknown while Ammonium chloride did not burn any specific color. The rest of the testing consisted of comparing CaCl2 to the unknown to make sure everything continued to line up. If the results did not match, then a reevaluation of what the unknown is would need to happen. All of the results lined up so more testing did not need to be done.
Part 2 Discussion:
The precipitation reaction performed lined up well with the theory. Only one of the reactants produced a precipitate with the unknown. A 300 mL solution was made with a reactant, the solute, and DI water. This was then filtered through a funnel and then the precipitate was able to be collected on the filter paper and transferred to a watch glass for it to be dried in the oven. The gravimetric analysis supports the hypothesis partially because it was not certain what the unknown was, but it did confirm it was one of the three possibilities previously stated. The experiment was only partially effective because the percent yield was only 69%. The reaction only made 1.78 grams of AgCl when theoretically it should’ve made 2.58 grams of AgCl.
Sources of Error:
Possible sources of error that could occur in the lab are contaminated glassware, inaccurate measurements, and uncontrollable reactions with the outside factors. Glassware can never be completely clean because of the amount of times that it has been used. It is also hard to tell when it could be clean. As measurements are taken, it is common for people to see different readings on an instrument. Also, electronic tools could be calibrated incorrectly leading to incorrect measurements. Even though the experiment was in a controlled environment there is a possibility for things in the air to react with solutions.
Changes to Experiment:
Conclusion:
The purpose of the lab was to identify an unknown substance using qualitative and quantitative testing. With the testing performed it was possible to compare known compounds to the unknown to help narrow down and eventually pinpoint what the unknown was. The hypothesis was confirmed that the unknown was either ammonium chloride, sodium oxalate, or calcium chloride. The unknown turned out to be calcium chloride, therefore solidifying the hypothesis. A variety of data was gained from multiple tests including solubility, flame test, precipitation reactions, pH tests, and conductivity. All evidence collected strongly supported the unknown being CaCl2 because all the tests yielded the same result or something very similar to it. The only problem was that the percent error was quite high for the precipitation reaction.
RESEARCH CONNECTION
Research Connection:
This article discussed contaminants found in drinking water and the effects of certain contaminants. The article specifically focuses on specific pathogen that has been linked to allergens and infections. Its’ focus brings attention to the health risks associated with tainted water sources in public residences. The United States Environmental Protection Agency sets standards of what is safe drinking water for people. Globally, the water safety standards differ slightly. Some countries include fungi in the safety and others believe that fungi are not harmful to humans but just cause an odor. It was found that in the Czech Republic that the water contained 50 individuals/mL. The researchers did answer their question of what was considered safe contaminants in water because they compiled a list of safe vs. unsafe organisms and listed what they contributed to.
References:
Ahmed, W.; Beale, D. Fungal Contaminants in Drinking Water Regulation? A Tale of Ecology, Exposure, Purification and Clinical Relevance. Environ. Res. Public Health 2017, 14(6), 636. Google Scholar. https://www.mdpi.com/1660-4601/14/6/636/htm (accessed October 7, 2019).
Essay Writing Service Features
Our Experience
No matter how complex your assignment is, we can find the right professional for your specific task. Contact Essay is an essay writing company that hires only the smartest minds to help you with your projects. Our expertise allows us to provide students with high-quality academic writing, editing & proofreading services.Free Features
Free revision policy
$10Free bibliography & reference
$8Free title page
$8Free formatting
$8How Our Essay Writing Service Works
First, you will need to complete an order form. It's not difficult but, in case there is anything you find not to be clear, you may always call us so that we can guide you through it. On the order form, you will need to include some basic information concerning your order: subject, topic, number of pages, etc. We also encourage our clients to upload any relevant information or sources that will help.
Complete the order formOnce we have all the information and instructions that we need, we select the most suitable writer for your assignment. While everything seems to be clear, the writer, who has complete knowledge of the subject, may need clarification from you. It is at that point that you would receive a call or email from us.
Writer’s assignmentAs soon as the writer has finished, it will be delivered both to the website and to your email address so that you will not miss it. If your deadline is close at hand, we will place a call to you to make sure that you receive the paper on time.
Completing the order and download