Criteria Assessed:
* Data Collection and Processing (DCP)
* Conclusion and Evaluation (CE)
Candidate Name:
Candidate Number:
International School, Singapore
AIM: To determine the molecular mass of an unknown alkali metal carbonate X2CO3 using titration.
INTRODUCTION:
Since substance Z is an alkali metal carbonate, it can safely be hypothesized that the compound is most likely to be the carbonate of Lithium, Sodium or Potassium since these are the only three alkali metal carbonates which are stable and safe to use in a school laboratory.
Alkali metal carbonates are basic in nature and dissolve in water hence forming basic solutions. These basic solutions can readily react with strong acids such as HCl to form a salt and water. Therefore, in order to determine the molecular mass of substance Z, its ability to form alkali solutions was exploited and hence, aqueous samples of substance Z was titrated against 0.1 molarity solutions of HCl.
Substance Z reacts with HCl according to the following balanced chemical equation:
X2CO3 (aq.) + 2HCl (aq.) → 2XCl (aq.) + CO2 (g) + H2O (l)
VARIABLES:
Independent Variables:
1. Mass of substance Z – The same digital balance was used to weigh out all the nine samples.
2. Volume of substance Z solution – 25.0cm3 of substance Z solution was used for each of the nine trial.
Dependent Variables:
1. Volume of 0.1M HCl required to neutralize 25.0cm3 of substance Z – The end-point was determined only when the methyl orange indicator completely changed color from yellow to orange.
Controlled Variables:
1. Molarity of HCl – It was 0.1M for all trials.
2. Drops of Phenolphthalein – For all trials, only three drops were used to prevent any misinterpretation of the reaction’s end point.
3. Volume of water used to dissolve all samples of substance Z – For all trials, only 250cm3 of distilled water was used.
4. Room temperature – All trials were performed in more or less, the same conditions.
APPARATUS AND CHEMICALS:
Quantity × Item
Purpose
1 x 100 cm3 beaker
To hold 0.1M HCl before pouring into burette.
1x 50cm3 burette (±0.05cm3)
To ensure volume of HCl used can be determined precisely since a burette is a precise instrument.
1x 250cm3 volumetric flask
To hold the solution of substance Z.
1x 25cm3 pipette (±0.03cm3)
To measure out 25cm3 of substance Z solution into Erlenmeyer flask for titration.
1x Erlenmeyer flask
To act as the reaction site and to hold the 25cm3 of substance Z solution.
1x retort stand
To hold the burette in place steadily to avoid accidents and inaccuracies.
1x glass funnel
To pour HCl into burette.
1x white tile
To place under the reaction site so that the color change in methyl orange indicator can be easily identified.
1x digital balance (±0.01g)
To weigh out samples of substance Z.
1x metal spoon
To efficiently scoop out small masses of substance Z.
1x 50cm3 beaker
To hold the initial mass of substance Z
Quantity × Chemicals
Purpose
Methyl Orange Indicator
To indicate the end-point of the acid-base reaction. Methyl Orange’s pH of 3.1-4.4 is appropriate for detecting pH of strong acids.
Excess of 0.1M HCl
To titrate substance Z solution against 0.1M HCl.
Excess of distilled water
To make solutions.
6.0g of solid substance Z
To make solutions containing 1.5g, 2.0g and 2.5g of substance Z
PROCEDURE:
1. The 50cm3 beaker was placed on the digital balance and the balance was calibrated to 0.
2. Using the metal spoon, slowly and carefully, 1.5g of substance Z was weighed out into the 50cm3 beaker.
3. Distilled water was added to completely dissolve the solid mass of substance Z.
4. The solution was poured into the 250cm3 volumetric flask making sure no solid or solution was left behind in the 50cm3 beaker.
5. Enough distilled water was added to make a 250cm3 solution in the 250cm3 volumetric flask.
6. The 250cm3 of substance Z solution was kept aside.
7. Now, the 50cm3 burette was clamped onto the retort stand.
8. 0.1M HCl was poured from the stock solution container into the 100cm3 beaker.
9. Using the glass funnel, the burette was filled with 0.1M HCl up to the 0.00cm3 mark.
10. 25cm3 of substance Z solution was pipetted out into the Erlenmeyer flask.
11. The reaction site, was kept on top of the white tile and 3 drops of methyl orange indicator was added to the 25cm3 solution of substance Z solution.
12. The process of titration was started keeping in mind to keep swirling the flask at a constant rate.
13. Once orange color was obtained, the amount of 0.1M HCl used was recorded.
14. The experiment was repeated 2 more times with 1.5g of substance Z, 3 times with 2.0g of substance Z and finally, 3 times with 2.5g of substance Z.
15. All nine readings were recorded in the pre-made data tables.
Safety Precautions:
1. Throughout the experiment, a lab coat was worn so that any spills do not cause damage to clothes or body.
2. Covered shoes and Safety goggles were worn to avoid damage from spillage of HCl.
3. The work-table was wiped clean and dried before and after the experiment.
RAW DATA COLLECTION:
Volume of HCl required to neutralize each trial of each sample of substance Z solution was noted by reading the lower meniscus of the solution in the burette.
Mass of substance Z used = 1.5g
Trial 1
Trial 2
Trial 3
Volume of substance Z solution (±0.03cm3)
25.0
25.0
25.0
Volume of HCl required for neutralization (±0.10cm3)
27.6
28.1
27.9
Mass of substance Z used = 2.0g
Trial 1
Trial 2
Trial 3
Volume of substance Z solution (±0.03cm3)
25.0
25.0
25.0
Volume of HCl required for neutralization (±0.10cm3)
37.2
36.8
37.3
Mass of substance Z used = 2.5g
Trial 1
Trial 2
Trial 3
Volume of substance Z solution (±0.03cm3)
25.0
25.0
25.0
Volume of HCl required for neutralization (±0.10cm3)
46.8
47.5
47.4
Table 1: Volume of HCl used to neutralize substance Z solutions in all trials.
Qualitative Observations
In each trial, it was observed that the solution’s color changed from yellow to orange.
Bubbling could be seen while the reaction between substance Z and HCl was taking place. This indicated that a gas was being expelled (in this case, carbon dioxide).
The reaction site gave off very slight amounts of heat which could be felt with bare hands.
DATA PROCESSING:
Average volume of HCl required to completely neutralize each of the basic substance Z solutions is determined by taking the arithmetic mean of the all the three trials for each solution containing 1.5g, 2.0g and 2.5g of substance Z.
Sample calculation for finding the average volume of HCl required to completely neutralize 25.0cm3 solution containing 1.5g of substance Z:
= = 28.0cm3.
Uncertainty for the value of average volume of HCl required for complete neutralization is ±0.10cm3 since averaging values do not lead to change in uncertainties.
This data is represented in the following table.
1.5g of substance Z
2.0g of substance Z
2.5g of substance Z
Volume of substance Z solution (±0.03cm3)
25.0
25.0
25.0
Average volume of HCl required for neutralization (±0.10cm3)
28.0
37.1
47.2
Table 2: Average volumes of substance Z solution and HCl used in all trials.
To determine the molar mass of X2CO3, we need to find the moles of X2CO3 that are present in 25.0cm3 of substance Z solution.
Part 1: Determining number of moles of X2CO3 in 1.5g of substance Z
Since 1.5g was used to make 250cm3, 25cm3 of solution is assumed to have 0.15g of X2CO3.
Number of moles (mol) = Concentration (mol/dm3) x volume (dm3). Therefore, moles of HCl = Concentration of HCl (mol/dm3) × Volume of HCl (dm3) = 0.1 × = 0.0028 moles
HCl reacts with substance Z according to the following balanced chemical equation:
X2CO3 (aq.) + 2HCl → 2XCl (aq.) + CO2 (g) + H2O (l)
Therefore, it can be seen from the balanced equation of the reaction that every two moles of HCl require one mole of X2CO3 which means that 0.0028moles will require 0.0014moles of X2CO3.
Since the reaction had reached completion, it can be assumed that the required 0.0014 moles of X2CO3 was present in the 25cm3 of the solution which was assumed to have 0.15g of X2CO3. Therefore, total mass of 0.0014 moles of X2CO3 is considered to be 0.15g.
This formula can be rearranged to make molecular mass the subject → .
In this case, = = 107.14g/mol
Since, molecular mass of the Carbonate Ion (CO3-2) = 60.01g/mol; atomic mass of X is calculated by subtracting the mass of carbonate ion from the mass of X2CO3 and dividing the result by two; = 23.56 g/mol.
Part 2: Determining number of moles in 2.0g of substance Z.
Since 2.0g was used to make 250cm3, 25cm3 of solution is assumed to have 0.20g of X2CO3.
Moles of HCl = 0.0037moles.
Therefore, 0.20g had 0.00185moles of X2CO3.
Therefore, molecular mass of X2CO3 = = 108.1g/mol
Atomic mass of X = = 24.045g/mol
Part 3: Determining number of moles 2.5g of substance Z.
Since 2.5g was used to make 250cm3, 25cm3 of solution is assumed to have 0.25g of X2CO3.
Moles of HCl = 0.00472moles.
Therefore, 0.25g had 0.00236moles of X2CO3.
Therefore, molecular mass of X2CO3 = = 105.93g/mol
Atomic mass of X = =22.945g/mol.
Summarizing the Results: The results of all the nine trials of titration of 0.1M HCl against the X2CO3 solutions are tabulated below:
Mass of X2CO3 in 25cm3 of X2CO3 solution (g)
Average volume of HCl required to neutralize 25.0cm3 of the X2CO3 solution (cm3)
Molecular Mass of X2CO3 derived (g.mol-1)
Atomic Mass of X derived (g.mol-1)
Atomic mass of X derived from the three trials of each sample.
The average atomic mass of X = = 23.52g.mol-1.
Since the atomic mass of X (23.52g.mol-1) is closest to the atomic mass of Sodium (22.99g/mol); it can be concluded that substance Z (X2CO3) is Sodium Carbonate (Na2CO3).
Therefore, the relative molecular mass of Na2CO3 = 107.05g/mol.
Error Propagation:
Total error = Total random error + Total systematic error.
To calculate the total random error, the percentage uncertainty of the lowest reading on each instrument shall be added together.
Percentage uncertainty =
Total Random Error
0.12 + 0.36 + 0.67 = 1.15%
Table 3: Total Random Error Calculation.
Since X is determined to be Sodium, the literature value to be considered is the molecular mass of Na2CO3 which is 105.99g/mol (www.sigmaaldrich.com).
Therefore, percentage error in the derived value for the relative molecular mass of Sodium Carbonate
CONCLUSION AND EVLUATION:
The results of our experiment have yielded very accurate results because the derived relative molecular mass of X2CO3, 107.05g/mol, is impressively close the literature value of 105.99g/mol. In fact, the total error percentage is smaller than the random error percentage; 1.00% < 1.15% which means that the literature value for the relative molecular mass of X2CO3 (105.99g/mol) lies within the range of derived values, 105.44g/mol to 108.66g/mol. Due to a respectably high accuracy and consistency in all our values, I can conclude with a large magnitude of confidence that the experiment was successful and indeed the compound Z, X2CO3 was Sodium Carbonate, Na2CO3.
I feel that one of our major strengths in yielding such accurate results was our ability to recognize the end point of the acid-base titration with considerable accuracy. This made sure that the volume of 0.1M HCl required to neutralize the substance Z solution was not under or over stated.
Secondly, the high accuracy in the experimental data also owes to the fact that the compound Na2CO3 is stable in air which means that other than the inherent impurities, there is not much scope for contamination of the compound due to any significant reaction with air, like in the case of NaOH or other similar chemicals where storage under air tight conditions is a must.
Lastly, another factor that could be responsible for high accuracy is that while making the solutions of substance Z, not a single visible droplet of substance Z solution was left behind because the beaker had a non-stick coating on its inner walls and on top of that, all of us lab partners made sure that beaker was help in the up-side position for long enough for all solution to fall out into the volumetric flask.
Despite yielding quite accurate experimental results, there were limitations with the equipment and some systematic error was unavoidable. One such limitation was the inability of the digital balance to reach higher degrees of precision. Although the digital balance used was very precise with an uncertainty of only ±0.1g, the masses that were weighed out were very small and hence even a small absolute uncertainty translated into a large percentage uncertainty. In this case, the percentage uncertainty for the readings of the digital balance was 0.67% which is the largest percentage uncertainty in comparison to the other instruments such as the burette or the pipette. If these uncertainties could be avoided a result much closer to the literature would be possible to obtain.
Some other possible shortcomings to this experiment are also listed below:
1. The solid substance Z might not be pure Sodium Carbonate and some impurities present could have led to the overstatement of the value for the molecular mass of X2CO3. These impurities might have been introduced due to long storage periods and moisture from the air. Therefore, a more pure sample should preferably be used and it should be sifted to remove any clumps of moisture which might add unwanted mass to the sample.
2. The molarity of HCl was determined only from the label on the stock solution. However, over time, evaporation of water from the solution may lead to increase in molarity which in turn would lead to overstatement of the value for the molecular mass of X2CO3. This problem can be solved rather easily by simply making a standardized solution in the lab itself eliminating any dependence on the labels.
3. Parallax error in reading the burette might have led to overstatement or understatement of the value for the molecular mass of X2CO3. This can be avoided by using a mirror against the markings to obtain a more accurate readings and reading only the lower meniscus of the liquid in the burette.
4. Due to the continued usage of the white tile by various students for various experiments, it is unavoidable to have some stains on it. Our white tile had very minute yellowish stain on it which might have interfered with the orange color leading to some inaccuracies in reading the end-point of the reaction. Nonetheless, as much care as possible was taken but a very minor systematic error was unavoidable.
Overall, I would say that the experiment was satisfactory in the given conditions where both time and resource were limited. Alternate methods to obtain the molecular mass of unknown substance Z could be used in addition to this method after which, the results can be analyzed to give a much more accurate value for the molecular mass of X2CO3. However, in the time constraints of our lab classes, it was not possible to perform both experiments with the same level of accuracy and we chose not to perform two experiment because that would compromise with the accuracy of both.
Essay Writing Service Features
Our Experience
No matter how complex your assignment is, we can find the right professional for your specific task. Contact Essay is an essay writing company that hires only the smartest minds to help you with your projects. Our expertise allows us to provide students with high-quality academic writing, editing & proofreading services.Free Features
Free revision policy
$10Free bibliography & reference
$8Free title page
$8Free formatting
$8How Our Essay Writing Service Works
First, you will need to complete an order form. It's not difficult but, in case there is anything you find not to be clear, you may always call us so that we can guide you through it. On the order form, you will need to include some basic information concerning your order: subject, topic, number of pages, etc. We also encourage our clients to upload any relevant information or sources that will help.
Complete the order formOnce we have all the information and instructions that we need, we select the most suitable writer for your assignment. While everything seems to be clear, the writer, who has complete knowledge of the subject, may need clarification from you. It is at that point that you would receive a call or email from us.
Writer’s assignmentAs soon as the writer has finished, it will be delivered both to the website and to your email address so that you will not miss it. If your deadline is close at hand, we will place a call to you to make sure that you receive the paper on time.
Completing the order and download